Kraft Coil Insulation®
|
|
Test
|
|
|
Typical Values
|
ASTM Method
|
|
Caliper
|
|
typical
|
0.001
|
ASTM-D-202-55T
|
|
|
|
minimum
|
0.00095
|
|
|
|
|
maximum
|
0.00105
|
|
|
Basis Weight Lb.
|
|
24” x 36” – 500 sheets
|
13.5
|
ASTM-D-646-50
|
|
Apparent Density
|
|
(grams per cc.)
|
0.88
|
ASTM-D-202-55T
|
|
Tensile
|
MD
|
lb. / in.
|
13.0
|
|
|
|
TD
|
lb. / in.
|
7.0
|
|
|
Tear Grams
|
MD
|
|
|
ASTM-D-202-55T
|
|
|
TD
|
|
|
|
|
Ash
|
|
max %
|
0.45
|
ASTM-D-202-55T
|
|
pH
|
|
|
6.5 – 7.5
|
ASTM-D-202-55T
|
|
Dielectric Strength
|
|
volts – 1 ply.
|
430.0
|
ASTM-D-202-55T
|
|
Conductive paths
|
max
|
per. sq. ft.
|
1.0
|
ASTM-D-202-55T
|
|
Conductivity
|
max
|
micromhos
|
15.0
|
ASTM-D-202-55T
|
|
Chloride
|
max
|
ppm.
|
16.0
|
ASTM-D-1305-54T
|
|
CONDITIONS: Determination of the suitability of the
material to the use contemplated is the user’s responsibility. Users
assume all risks resulting from the use of our products and must confirm
adaptability through their own tests. Liability will in no event exceed value of
the material sold.
|
|
|
eisp_002_Kraft_Coil_Ins
|